Ethernet Switch

Ethernet Switch

  • Power supply/signalling contact 1 and 2: 1x plug-in terminal block 2-pole, 1x plug-in terminal block 2-pole
  • V.24 access: 1x RJ11 socket
  • USB interface: 1x USB to connect the auto configuration adapter ACA21-USB

The 8 Port Fast Ethernet Switch is managed, for DIN rail store-and-forward-switching and has a fanless design.

 
Operating voltage  
Power supply 1 20 to 30 V DC
Power supply 2 20 to 30 V DC
Power consumption 14 W
   
Dimensions 120 x 137 x 115 mm
Weight 1.0 kg
Protection category IP30
Stability  
IEC 60068-2-27 shock 15 g, 11 ms durations, 18 shocks
IEC 60068-2-6 vibration 1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min
   
Permissible operating temperature -40°C – 85°C
Permissible storage temperature -40°C – 85°C
Ambient Relative Humidity 10% - 95%
   
Management Serial Interface, Web-Interface, SNMP V1/V2, HiVision Filetransfer SW http/TFTP
Diagnostic LEDs, Log-File, Syslog, Relais Contact, RMON, Port Mirroring 1:1 nad n:1, Topology Discovery 802.1AB
Configuration Comand Line Interface (CLI), TELNET, BootP, DHCP, DHCP option 82, HIDiscovery
Security Port Security (IP und MAC) with several addresses, SNMP V3, SSH, Authentication (IEEE802.1x), Radius Authentication for SNMPv3 (Web)
Redundancy functions HIPER-Ring, Fast HIPER-Ring, MRP, MSTP, RSTP - IEEE802.1D-2004, MRP and RSTP simultaneously, Link Aggregation, multiple Rings
Filter QoS 4 Classes, Portpriority (IEEE 802.1D/p), VLAN (IEEE 802.1Q), shared VLAN learning, Multicast (IGMP Snooping/Querier), Multicast Detection unknown Multicast, Broadcastlimiter, Fast Aging, Multicast GMRP IEEE 802.1D
Industrial profiles EtherNet/IP und PROFINET (2.2 PDEV, GSDML Stand-alone Generator, automatic device exchange) Profile inclusive, configuration and diagnostic via automation software, e.g. STEP7, or Control Logix
Time synchronization SNTP Server, Realtime Clock with energy storage
Flow control Flow Control 802.3x, Port Priority 802.1D/p, Priority (TOS/DIFFSERV), Prio (MAC/IP), Prio Mapping (TOS Layer2), Traffic Shaping (Unicast, Multicast, Broadcast) Ingress / Egress
   
EN 61000-4-2 electrostatic discharge 8 kV contact discharge, 15 kV air discharge
EN 61000-4-3 electrostatic field 35 V/m (80-2700 MHz); 1 kHz, 80% AM
EN 61000-4-4 fast transienten (burst) 4 kV power line, 4 kV data line
EN 61000-4-5 surge voltages power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line IEEE1613: power line 5 kV (line/earth)
EN 61000-4-6 conducted immunity 3 V (10 kHz-150 kHz), 10 V (150 kHz-80 MHz)
EN 61000-4-16 low-frequency transiens 30 V, 50 Hz consistently; 300 V, 50 Hz 1 s
   
FCC CFR47 Part 15 FCC 47 CFR Part 15 Class A
EN 55022 EN 55022 Class A